英文:Practical design of a liquid rate gyroscope using an electro-conjugate fluid 
著者
和文: 竹村 研治郎, 横田 眞一, T. Imamura, 枝村 一弥, H. Kumagai.  
英文: K. Takemura, S. Yokota, T. Imamura, K. Edamura, H. Kumagai.  
言語 English 
掲載誌/書名
和文: 
英文:Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering 
巻, 号, ページ Vol. 223    No. 6    pp. 727-736
出版年月 2009年 
出版者
和文: 
英文:Professional Engineering Publishing 
会議名称
和文: 
英文: 
開催地
和文: 
英文: 
DOI https://doi.org/10.1243/09596518JSCE747
アブストラクト An electro-conjugate fluid (ECF) is a kind of dielectric fluid that works as a functional/smart fluid generating a powerful jet flow (ECF jet) when subjected to a high d.c. voltage. The authors previously proposed the first liquid rate gyroscope in the world using ECF. The ECF liquid rate gyroscope proposed uses the drift of the ECF jet due to the Coriolis force when an angular motion is applied. The contribution of the proposed concept to gyroscope technology is that it provides the possibility of a low-cost micro gyroscope with inherent robustness to external impact. To move beyond a mere laboratory curiosity, the present paper describes the practical design of an ECF liquid rate gyroscope and characterizes the prototype. The ECF liquid rate gyroscope developed in this study has a scale factor, range of detection, resolution, and linearity of 32 mV/(°/s), ±400°/s, 0.04°/s, and 2 per cent of full scale (with a range of ±60°/s), respectively. These results show that the ECF liquid rate gyroscope could possibly become the next generation standard of micro gyroscopes